APC Galaxy UPS service in Canada

GDF Technologies maintains and repairs APC Galaxy three-phase UPS across Canada, from current Galaxy VS, VL, VX and VXL systems to discontinued Galaxy 3500, 5000, 7000 and VM frames. Call 514-252-8324, 24/7: rapid dispatch, 1 to 3 h in the Montreal area, same day in Quebec City, Toronto and Ottawa, 24 to 48 hours elsewhere.

24/7
service line
Same day
Montreal, Quebec City, Toronto, Ottawa
24 to 48 h
elsewhere in Canada
4 business hours
to a written quote
Lifecycle

Which Galaxy do you have, and its status

Status as shown on Schneider Electric’s Canadian product pages, read on 12 October 2026. Dates differ by part number, so check the reference on your own nameplate.

Galaxy modelStatus on se.com CanadaReplacement Schneider Electric names
Galaxy VS, 10 to 150 kWCurrent rangeNot applicable
Galaxy VL, 200 to 500 kW and 1600 to 2000 kWCurrent rangeNot applicable
Galaxy VX, 500 to 1500 kWCurrent rangeNot applicable
Galaxy VXL, 500 to 1250 kWCurrent rangeNot applicable
Galaxy 3500 (range)“Limited stock exists”; the part pages no longer open on se.com CanadaGalaxy VS range
MGE Galaxy 5000 80 kVA (G5TUPS80)Discontinued on Dec 11, 2025; to be end-of-service on Dec 31, 2030Galaxy VS 80 kW (GVSUPS80KHS)
MGE Galaxy 7000 500 kVA (G7TUPS500)Discontinued on Aug 29, 2023; to be end-of-service on Dec 31, 2031Galaxy VL range
Galaxy VM 180 kVA single, 480 V (GVMSB180KGS)Discontinued on Jan 31, 2023; end-of-service on Apr 19, 2023Not named on the page
Galaxy VM 160 kVA parallel, 480 V (GVMPB160KG65S)End-of-service on Apr 27, 2026Galaxy VX 500 kVA (GVX500K500NHS)
MGE Galaxy 300 (G3HT10K3IB2S, G3HT40KHS) and Galaxy 5500 (G55TUPSU20HS, G55TUPSM30HB15S)Not listed: these part pages open the product overviewCheck your part number

What the words mean, in Schneider Electric’s own terms: discontinued is the end of commercialization, the last date it accepts an offer for that reference, while after-sales services (repair, spare parts) continue until its end of life. Past end of service, plan the replacement; GDF keeps servicing the unit in the meantime.

What a visit covers

Servicing a Galaxy: what a visit covers

Online when the load is critical

On the maintenance bypass, the Galaxy VS manual describes the load as supplied with unprotected power from bypass. GDF prefers online maintenance for critical loads and plans any bypass work with you.

Event log and alarms

The display and event log come first: outages, transfers, faults and the last self-test. For bypass alarms on a Galaxy VS, see Galaxy VS bypass errors and essential tests.

Batteries

String float voltage, block voltage and internal resistance, with battery temperature, and a look for swelling, acid and corrosion.

Firmware and commissioning

Firmware updates where they apply, with the event logs checked after maintenance (firmware updates on APC Symmetra and Galaxy), and start-up of new or replacement units (commissioning a Galaxy).

Discontinued frames

Galaxy work in GDF’s database covers 20 threads and 17 quotes. On older frames, parts get scarce: plan the replacement while the unit is still serviceable.

Replacement

Schneider Electric names a Galaxy V successor for most of the parts above. GDF also quotes XPC, a certified partner, as a replacement, sized to the measured load. See replacing a discontinued three-phase UPS.

From the field

A Galaxy 3500 at end of support: one site

At a municipal water treatment plant in the Montreal region, the annual PM found an APC Galaxy 3500 / Smart-UPS VT of 20 kVA, a model discontinued in 2021 and no longer serviced by the manufacturer since 2023, according to the GDF report for that unit. Its 5-year-old batteries were degrading and losing acid, and a network card was installed but not connected. The recommendation: replace the batteries without delay, connect the card for alerts, and plan the replacement of the frame.

FAQ

Questions about APC Galaxy service

Do you service APC Galaxy UPS in Canada?

Yes: current Galaxy VS, VL, VX and VXL systems and discontinued Galaxy 3500, 5000, 7000 and VM frames. The line is open 24/7 at 514-252-8324.

My Galaxy 3500 is discontinued. Can it still be serviced?

Schneider Electric’s Canadian range page now reads “Limited stock exists” and points to the Galaxy VS range for replacements. GDF still maintains these units and replaces their batteries; plan the frame replacement in parallel.

What is the difference between discontinued and end of service?

Discontinued is the end of commercialization, the last date Schneider Electric accepts an offer for that reference. After-sales services such as repair and spare parts continue until its end of life. Many part pages also give an end-of-service date.

What replaces a Galaxy 5000, 7000 or VM?

On se.com Canada: Galaxy VS 80 kW for the MGE Galaxy 5000 80 kVA, the Galaxy VL range for the MGE Galaxy 7000 500 kVA, and Galaxy VX 500 kVA for the Galaxy VM 160 kVA parallel unit. Check your own part number.

Can a Galaxy be maintained without dropping the load?

GDF prefers online maintenance for critical loads, which keeps the load protected. On the maintenance bypass the load is fed with unprotected power, so bypass work on critical loads is planned with you.

How fast can a technician reach a Galaxy site?

Rapid dispatch: 1 to 3 h in the Montreal area, same day in Quebec City, Toronto and Ottawa, and 24 to 48 hours elsewhere in Canada. Call 514-252-8324 at any hour.

Galaxy in alarm, or due for service?

Send the model, the part number from the nameplate and the alarm. You receive a written quote within 4 business hours.

Sources

  • Schneider Electric Canada, Galaxy master range page, Galaxy VL and Galaxy 3500 range pages, and part pages G5TUPS80, G7TUPS500, GVMSB180KGS, GVMPB160KG65S, read on 12 October 2026.
  • Schneider Electric, Galaxy VS operation manual 990-5910G.
  • GDF Technologies work database: Galaxy threads and quotes, field procedure, and the case described without client or date.