Vertiv & Liebert UPS Service & Support in Canada
Expert maintenance, battery replacement, and 24/7 emergency response for all Vertiv and Liebert UPS systems, including legacy Emerson Network Power and Chloride units. Serving data centres, healthcare, government, and industrial facilities across Canada.
Who services Vertiv and Liebert UPS systems in Canada?
Vertiv and Liebert UPS systems in Canada are serviced by Vertiv’s own service organisation and by multi-brand service companies such as GDF Technologies. GDF services Vertiv and Liebert UPS across Canada, 24/7: preventive maintenance, battery replacement, alarm diagnosis, bypass testing and emergency repair on the Liebert GXT5, GXT, PSI, ITA2, EXM, EXL S1, NX, NXC and APM, plus legacy Emerson Network Power and Chloride units, including models Vertiv no longer supports. If your unit is still under Vertiv warranty or a Vertiv service contract, contact Vertiv first. For out-of-warranty units, end-of-life models and mixed fleets, call GDF at 514-252-8324. Every visit ends with a written report for compliance and budgeting.
- Company: GDF Technologies, a UPS service company based in Montreal, in business since 2012
- Services: 24/7 emergency repair, preventive maintenance, battery replacement, bypass and load-bank testing, supply of new Vertiv UPS (started up by Vertiv)
- Vertiv / Liebert models: Liebert GXT5, GXT, PSI, ITA2, EXM, EXL S1, NX, NXC and APM, plus legacy Emerson Network Power and Chloride units
- Coverage: on-site service across Canada with 24/7 emergency dispatch; same-day in Montreal, Quebec City, Toronto and Ottawa
- Phone (24/7): 514-252-8324
- Email: support@gdftech.com
Vertiv / Liebert UPS service by city: Montreal · Toronto · Ottawa · Quebec City · Vancouver · Calgary · Edmonton · Winnipeg · Hamilton · Mississauga · Brampton · Halifax · Surrey · Moncton · Saskatoon · Regina
Updated October 2026.
How is a Vertiv Liebert UPS maintained?
The video starts at the “Vertiv Liebert” chapter of our UPS maintenance video; the full video covers the eight checks of a preventive maintenance visit.
Chapters: 0:00 Intro · 0:13 Why it matters · 0:35 Check 1. The plan · 1:03 Check 2. The room · 1:16 Check 3. The event log · 1:31 Check 4. The batteries · 2:19 Check 5. The parts that wear out · 2:51 Check 6. The tests · 3:11 Check 7. The major maintenance · 3:45 APC and Schneider Electric · 4:05 Eaton and Powerware · 4:23 Vertiv Liebert · 4:41 Check 8. The report · 5:03 Recap: minor vs major maintenance · 5:42 Our services
Chapters and transcript
Intro
A UPS keeps your equipment running when the power fails, but only if it’s maintained. This is what a maintenance visit covers: the eight checks we do on APC, Eaton, Vertiv and other UPS systems.
Why it matters
Why does it matter? At one government office, the display said more than two hours of backup. When we tested the batteries behind it, six strings out of eight had failed. Here’s how we catch that before the power goes out. The plan, the room, the event log, the batteries, the parts that wear out, the tests, the yearly major maintenance, and the report.
Check 1. The plan
Check one happens before we arrive: the plan. We settle three things with you. When we can work, whether the UPS can go on bypass, and who signs off on any test. On bypass, your equipment runs straight off building power, with no battery behind it. A hospital in the Quebec City region asked whether the visit would put their UPS on bypass. Our advice: do it online, so their equipment stays protected. Most of the visit works that way.
Check 2. The room
Check two: the room. We look at the temperature, the airflow and the dust. Heat takes years off a set of batteries. At that same office, heat was building up in a poorly ventilated room.
Check 3. The event log
Check three: the event log. It shows the recent power failures, every switch to battery or bypass, and the alarms nobody saw. There, the log showed eight power failures in eight months. That UPS had been working hard.
Check 4. The batteries
Check four: the batteries. On APC, Eaton and Vertiv UPS alike, this is where we find most problems. We look for swollen cases, acid at the vents and corrosion on the terminals. Then we measure every block, one by one: its voltage and its internal resistance. Internal resistance tells us more than voltage does. A block whose resistance is much higher than its neighbours is failing, even when its voltage looks normal. The display only estimates runtime. It doesn’t measure each block the way we do. At that office, six of the eight strings failed the test. There was acid at most of the vents, and the batteries were only four years old. Standard UPS batteries last three to five years. Long-life ones can go eight years or more, in a cool room.
Check 5. The parts that wear out
Check five: the parts that wear out. Fans, air filters and capacitors. Before we open a door on a running UPS, we read its arc-flash label and suit up to match it. A clogged filter makes the UPS run hot, so we clean it or replace it. With the UPS carrying your load, and the covers off in full protective gear, we scan the connections with a thermal camera. A loose connection shows up hot long before it burns. The more load on the UPS, the better it shows.
Check 6. The tests
Check six: the tests. If the batteries passed, and you agree, we switch the UPS to battery for a short test. That shows it picks up the load cleanly. If the batteries failed, we skip it. We don’t gamble with your equipment. A short test doesn’t prove your full runtime. If you need that number, we plan a timed runtime test with you.
Check 7. The major maintenance
Check seven: the major maintenance. Everything so far is the minor maintenance, done with the UPS online. Most sites also need a major one each year. It’s the one time your equipment runs without the UPS behind it, so we plan the window with you. We move the load to the maintenance bypass, isolate the UPS and its batteries, lock them out, and test for voltage before anyone works inside. Then we check the torque on the power connections, clean out the dust and change the filters. Before your load goes back on, we run the UPS through each operating mode.
APC and Schneider Electric
Each brand has its own weak spots. On an APC Symmetra PX or LX, the batteries slide out as modules, so we can swap them with your equipment still running. Schneider Electric stopped servicing the APC Galaxy 3500 in 2023. We still maintain them, and we help you plan the replacement before parts get hard to find.
Eaton and Powerware
Eaton’s 9155, 9355 and 93PM often keep their batteries in separate cabinets, in several strings. We test every string on its own. On older Eaton and Powerware units, capacitors and fans wear out with age. We replace them on a schedule, before they fail.
Vertiv Liebert
A hospital can have a whole fleet of Liebert GXT units. We test every one, then plan the replacements by age and result. On three-phase units like the Liebert EXM, it’s the full eight checks. Mitsubishi, Toshiba, Tripp Lite: we service them all, and you get the same report.
Check 8. The report
Check eight: the report. You get it in writing. Every reading, photos and thermal images, and a green, yellow or red rating for each unit. Then a short list of what to do next, starting with the most urgent. For that office, the batteries came back red: replace them now. And since the UPS itself was seventeen years old, we told them to start planning a new one.
Recap: minor vs major maintenance
To recap, here’s what each visit includes. A minor maintenance keeps your UPS online. We check the room, the log, the readings and every battery block. Then the parts that wear out, a thermal scan, and a short test if the batteries pass. A major maintenance adds a planned window on bypass. The UPS and batteries are isolated and locked out, the torque is checked, the inside is cleaned, and every operating mode is tested. Both end with a written report. If your batteries are four years old or more and nobody has tested them, have them tested before your next outage.
Outro
GDF Technologies does this visit across Canada. We offer support when you need it, and when something fails, we’re there day or night. We also offer extended warranties on parts and labour. And when it’s time for a new UPS, we do the consulting and engineering with you, from configuration to delivery and installation. Call us, or ask for a quote at gdftech.com. You’ll hear back within four business hours.
Vertiv / Liebert UPS support: who to call
| Your situation | Who to call |
|---|---|
| Unit under Vertiv warranty or a Vertiv service contract | Vertiv, directly |
| Out of warranty, no service contract | GDF Technologies or Vertiv, your choice |
| Vertiv / Liebert model past end of service life (EOSL) | GDF Technologies: service and parts |
| Battery alarm, failed self-test or short runtime | GDF Technologies: diagnosis first, then replacement batteries |
| Outage or alarm right now, any brand | GDF Technologies, 24/7: 514-252-8324 |
| Mixed fleet (APC, Eaton, Vertiv, Tripp Lite) under one contract | GDF Technologies |
Vertiv and Liebert are trademarks of Vertiv.
Buy Vertiv / Liebert UPS systems in Canada
Beyond service work, GDF Technologies supplies Vertiv and Liebert UPS systems across Canada, from single rack units to multi frame three phase projects. Current supply covers GXT5 rack online units, ITA2 compact three phase systems, and EXM and APM modular three phase platforms, plus installed Liebert NX and NXC fleets. New Vertiv systems are started up by Vertiv to protect the factory warranty; we supply Vertiv UPS and handle maintenance, batteries and repairs from day one.
For stocked equipment and replacement batteries with published specifications, see three phase UPS families in stock at UPS Plus Battery. For sizing help, project quotes or trade in of the fleet being replaced, call 514-252-8324 or use the contact page; describe the load and the room and you receive a written proposal.
Already running Vertiv / Liebert equipment? The service side of this page covers preventive maintenance, emergency repair and battery replacement for existing fleets, whether or not the equipment was purchased from us.
Vertiv & Liebert UPS Models We Service
Vertiv (formerly Emerson Network Power) rebranded Liebert in 2016. GDF Technologies services all generations, current Vertiv products, legacy Liebert, and discontinued Emerson and Chloride units.
Vertiv Liebert GXT5
Online double-conversion, 500VA-10kVA. Rack/tower convertible. Widely deployed in server rooms, network closets, and edge computing environments.
Vertiv Liebert EXM / EXL S1
Three-phase, high-efficiency double conversion. The EXL S1 serves large data centres from 250 to 1,200 kW (480 V, 60 Hz); the EXM covers medium-size three-phase installations in data centres and industry.
Vertiv Liebert APM
Modular UPS, 15 to 150 kW per frame, scalable to 900 kW. Popular in large data centres requiring N+1 redundancy. Concurrent maintainability.
Liebert NX / GXT Series Legacy
Former Liebert branding, widely installed across Canada. Full maintenance and battery replacement supported. Parts sourcing for discontinued models.
Emerson Network Power Legacy
Pre-2016 Emerson-branded UPS including Chloride, Hiross, and Aros series. EOL maintenance, battery fabrication, and emergency support available.
Chloride UPS EOL
Single and three-phase Chloride units common in industrial and utility environments. GDF provides full lifecycle support including parts sourcing for discontinued lines.
Not seeing your model? Contact us, we service the full Vertiv/Liebert/Emerson portfolio.
What’s Included in Our Vertiv / Liebert UPS Service
Every intervention follows IEEE and CSA standards. You receive a full MOP (Method of Procedure) before work begins and an MSR (Maintenance Service Report) upon completion.
Preventive Maintenance
Complete system inspection: visual checks, capacitor and fan condition, thermal imaging, control board verification, battery impedance testing, and load bank validation. Scheduled to your SLA requirements.
Battery Replacement
OEM-equivalent VRLA and lithium battery replacement using high-rate VRLA batteries, Canadian-manufactured, warrantied. Runtime validation and compliant disposal documentation included.
Emergency Response
24/7 dispatch for Vertiv/Liebert alarms, bypass faults, and unexpected shutdowns. Rapid triage, temporary bypass coordination, and critical spares management across Canada.
CRAC / Cooling Integration
Vertiv also manufactures CRAC and CRAH units. GDF can coordinate UPS and cooling maintenance in a single contract, one provider for your complete critical infrastructure.
Maintenance Contracts
Annual contracts with defined SLAs, fixed pricing, and priority emergency response. Single units to multi-site enterprise fleets. Custom design for government procurement requirements.
Repairs & Legacy Support
Component-level repair for Vertiv/Liebert power electronics and control modules. Parts sourcing for Emerson and Chloride EOL models no longer supported by Vertiv.
Why GDF Technologies for Vertiv / Liebert UPS Service?
Vertiv’s own service arm prioritises new equipment sales. Third-party providers often lack depth on Emerson-era legacy units. GDF covers the full historical portfolio.
- ✓Full brand history coverageVertiv, Liebert, Emerson Network Power, Chloride, all generations, all models. No “we only support current Vertiv products” limitations.
- ✓Canadian-manufactured batteriesHigh-rate VRLA batteries replace OEM cells at equivalent or superior performance. Made in Quebec. Zero US tariff exposure on every battery we supply.
- ✓Government-proven credentialsGDF holds a Shared Services Canada contract supplying the Department of National Defence with UPS battery replacements, full compliance documentation available.
- ✓CRAC / UPS unified contractsVertiv makes both UPS and cooling. GDF can manage both under one maintenance agreement, simplifying vendor management and reducing administrative overhead.
- ✓Bilingual service, national reachFrench and English technical teams. Montreal, Ottawa, Toronto, Calgary, Vancouver, one contract, coast-to-coast coverage.
The Emerson → Liebert → Vertiv Confusion
“Many facilities managers don’t know whether they have a ‘Liebert’, an ‘Emerson’, or a ‘Vertiv’, it’s the same product line, rebranded twice. GDF services every generation without requiring you to decode the corporate history.”
, GDF Technologies field operations
Request a Vertiv / Liebert Service Quote
Tell us your model (or what’s on the nameplate), location, and service need. We respond within 4 business hours.
📧 support@gdftech.comIndustries We Serve
Vertiv and Liebert UPS systems are among the most widely deployed in Canadian enterprise and mission-critical environments. GDF has experience across all of these sectors.
Data Centres
Colocation, enterprise, edge, zero-downtime maintenance with bypass
Healthcare
Hospitals, imaging, life support, power reliability compliance
Government
Federal, provincial, DND, PSPC/SSC compatible
Industrial
Manufacturing, mining, process control, harsh environment capable
Telecom
Network nodes, central offices, broadcast, 24/7 SLA contracts
Frequently Asked Questions
What’s the difference between Vertiv, Liebert, and Emerson Network Power UPS?
They are the same product line under different ownerships. Emerson Electric owned the Liebert brand and rebranded it as “Emerson Network Power” for marketing purposes. In 2016, Emerson spun off this division and it became Vertiv. GDF services all three generations under one service agreement, no need to worry about the corporate history.
Do you service older Chloride UPS units?
Yes. Chloride (acquired by Emerson, now Vertiv) produced three-phase UPS systems widely used in industrial and utility environments. GDF provides full maintenance, battery replacement, and parts sourcing for Chloride units, including models no longer supported by Vertiv.
Can you handle both the Vertiv UPS and the Liebert CRAC units in one contract?
Yes. GDF can include both UPS and cooling (CRAC/CRAH) maintenance under a single annual contract. This simplifies vendor management, unifies scheduling, and reduces the risk of maintenance gaps between interdependent systems.
How quickly can you respond to a Vertiv/Liebert UPS emergency in Canada?
GDF dispatches 24/7 and responds within 4 business hours. Rapid emergency dispatch: 1 to 3 h in the Montreal area, same day in Quebec City, Toronto and Ottawa-Gatineau; 24 to 48 hours elsewhere in Canada, including Calgary and Vancouver. Emergency SLAs are defined in your maintenance contract.
Do your replacement batteries void the Vertiv/Liebert warranty?
For out-of-warranty systems, the majority of installed Vertiv/Liebert UPS, our high-rate VRLA equivalent batteries are the appropriate replacement. Under Canadian competition guidelines, using equivalent batteries in out-of-warranty systems does not void infrastructure warranties.
Get a Vertiv / Liebert UPS Service Quote Today
Tell us what’s on the nameplate, your location, and what you need. Our team responds within 4 business hours, 24/7 for emergencies.
Monday-Friday 8am-5pm EST · 24/7 emergency dispatch available
We also stock Vertiv and Liebert replacement batteries for the GXT and PSI series.