Three-Phase UPS Systems for Critical Infrastructure

Sales, installation, certified commissioning and 24/7 maintenance for three-phase UPS systems from 10 to 800 kVA. APC Galaxy, Eaton 93PM, Vertiv EXL, XPC, Delta, Toshiba, Mitsubishi, Canada-wide.

Running critical power in a data center or server room? See our data center UPS service and maintenance across Canada.

GDF Technologies
7
Brands Supported
800
kVA Max. Supported
24/7
Emergency Response
🖥️ Data Centers
🏥 Medical
⛏️ Mining
🏭 Industrial
⚡ Telecom
🏛️ Government
Three-Phase Technology

Double Conversion, Redundancy & Continuity

Three-phase UPS systems for critical infrastructure exclusively use online double conversion, guaranteeing zero interruption regardless of grid quality.

⚡

Online Double Conversion

Zero transfer time, total electrical isolation, perfect sine wave output. Independent of grid fluctuations and generator-compatible. Industry standard for any critical site.

🔄

N+1 / N+N Redundancy

N+1 (standby module) or N+N (parallel systems) based on your SLAs. Hot-swappable modules, external maintenance bypass (XBDM/ISBM) for zero downtime.

🔧

Integration & Monitoring

MDP coordination, ATS/generator integration, SNMP/Modbus supervision, dedicated battery cabinets, PDUs and load bank testing. Certified commissioning report provided.

Brands & Models

Key Three-Phase UPS Models Supported

Sales, certified commissioning, maintenance, battery replacement and 24/7 emergency service for the following product lines.

APCSchneider Electric
Galaxy VX 10 to 500 kVAGalaxy VS 10 to 150 kVAGalaxy VXLSymmetra PX 10 to 500 kVAMGE Galaxy 3500Symmetra PX2

APC Galaxy (high-density datacenter) and Symmetra PX (modular scalable) are global references for data centers and hospitals. GDF provides commissioning, maintenance and batteries.

EatonEaton Corporation
93PM 10 to 200 kW9395 40 to 550 kVA9PX 5 to 11 kVA (3ph)Powerware 9390Powerware 9395

The Eaton 93PM is recognized for energy efficiency (≥97%) and modularity; Eaton no longer sells the 93E (the 9355 and 93PM replace it), and GDF still services installed units. The 9395 is a long-standing industrial reference. IPMVS supervision and BMS integration available.

VertivLiebert Series
Liebert EXL S1 250 to 1,200 kVALiebert NXC 16 to 200 kVALiebert EXM2Liebert APM 30 to 150 kWLiebert GXT5 (3ph)

Vertiv (Liebert) equips the largest North American data centers. The EXL S1 delivers exceptional efficiency with ECO mode. The APM is a ready-to-deploy modular solution.

XPCXtreme Power Conversion
E91 10 to 100 kVA (3-phase)M90 Modular N+1

GDF is a certified XPC partner. The E91 (three-phase online tower) and M90 (hot-swappable modular) are ideal for edge sites and small data centers. On-site commissioning activates the warranty.

DeltaDelta Electronics
Ultron HP 10 to 800 kVAUltron HPH 10 to 400 kVAUltron VH 10 to 120 kVAModulon DPH

Delta Ultron HP is a high-power three-phase solution recognized for reliability in data centers and industrial applications. N+1 redundancy, integrated bypass and advanced supervision.

ToshibaToshiba International
G9000 10 to 400 kVA4400 Series4600 Series4550 Series

Toshiba G9000 and the 4000 series deliver three-phase protection for data centers, hospitals and industry, recognized for durability and low maintenance costs.

MitsubishiMitsubishi Electric
9900AEGIS 80 to 225 kVA9900B 300 to 750 kVA9900CX 1,050 kVA9900D 1,200 to 2,000 kVASUMMIT 500 and 750 kVA

The Mitsubishi Electric 9900 series and SUMMIT Series cover large three-phase installations, and older 9800A, 9900A and 2033 units are still in service. GDF Technologies maintains current and legacy frames against the support phase Mitsubishi publishes for each model.

Model not listed? GDF Technologies supports all the above brands and many more.

📧 Contact Us

Certified Services

Three-Phase UPS Services Canada

From initial assessment to 24/7 emergencies, one partner for your critical power infrastructure.

🔍

Assessment & Design

Load analysis, redundancy (N+1/N+N), generator coordination, MDP selectivity and battery sizing.

✅

Commissioning & Warranty

Manufacturer-certified startup, warranty activation, functional and load testing, complete SAT report.

🔧

Preventive Maintenance

Scheduled visits, battery and capacitor testing, fan checks, thermography and firmware updates.

🔋

Batteries & Recycling

VRLA and Lithium, certified replacement, calibration, load testing and compliant recycling with certificates.

🚨

24/7 Emergency Response

Rapid response across Quebec and Canada. Remote triage, temporary solutions and critical parts planning.

🔄

Retrofit & Modernization

External maintenance bypass (XBDM/ISBM), PDU, SNMP/Modbus integration, relocation and secure decommissioning.

Need a Three-Phase UPS
in Canada?

Tell us your load (kW/kVA), required redundancy, form factor and site constraints. We’ll assess and plan the commissioning of your three-phase solution.

📧 Email GDF TechnologiesContact Form

Response guaranteed within 1 business day

Three-Phase UPS in Canada

GDF Technologies sells, installs and maintains three-phase UPS systems from 10 to 800 kVA across Canada. Our certified technicians service APC Galaxy/Symmetra, Eaton 93PM/93E, Vertiv Liebert EXL/NXC, XPC E91/M90, Delta Ultron, Toshiba G9000 and Mitsubishi 9900 series for commissioning, maintenance, batteries and 24/7 emergencies.

Double Conversion & Redundancy

All our three-phase UPS systems use online double conversion (zero transfer time). We configure N+1 or N+N redundancy, coordinate generator integration and perform load bank testing in accordance with IEC/CSA standards.

Three-Phase Commissioning

Commissioning by a certified technician is mandatory to activate the manufacturer warranty on professional three-phase UPS systems (APC Galaxy, Eaton 93PM, Vertiv EXL, XPC E91/M90). GDF Technologies performs these certified startups in Quebec, Ontario, British Columbia, Alberta and across Canada.

Capacity is only half of the specification. The other half is the IEC 62040-3 class the unit holds in each of its normal modes, which our UPS technical guide explains alongside the sizing method in watts and volt-amperes.

Contact GDF Technologies

For any three-phase UPS need in Canada, contact support@gdftech.com or visit our service centre: 5 Goodfellow Street, Delson, Quebec, J5B 1V2. Tel: (514) 252-8324.

Buy three-phase UPS systems in Canada

GDF Technologies supplies and installs three-phase UPS systems alongside servicing them. The families we quote most: Eaton 93PM and 9395, APC Galaxy VS and Galaxy VL, Vertiv ITA2 and APM2, Delta Ultron and Modulon, and Xtreme Power Conversion three-phase platforms. A supply quote can include electrical installation, battery cabinets sized to your runtime target, commissioning with a load and transfer test, and the maintenance plan that keeps the warranty meaningful.

For stocked three-phase families with published specifications, see the three-phase UPS family hub at UPS Plus Battery. For a project quote, call 514-252-8324 with the load, voltage and runtime target, and you receive a written proposal.