GDF Technologies supplies Vertiv and Liebert UPS systems to businesses across Canada. We help you pick the right model for your load and your room, then coordinate delivery and startup. Our team supports your fleet for its whole service life afterward.

Call 514 252 8324Request a quote

0 mstransfer time in double conversion (GXT5, ITA2)
500 VAto 20 kVA single phase
24/7emergency support across Canada

The lines we supply

Four families cover most single phase needs. Click a line to request a quote.

⚡

Liebert GXT5

500 VA to 20 kVA: double conversion

The online double conversion benchmark for servers and critical loads. Tower and rack formats, unity power factor, replaceable batteries. The 1500 VA and 3000 VA sizes are the most requested.

GXT5 quote →

🔌

Liebert PSI5

750 VA to 3000 VA: line interactive

The economical choice for switches, routers and small servers in branch offices and retail sites. Rack and tower formats.

PSI5 quote →

🖥️

Vertiv EDGE

500 VA to 3000 VA: edge of network

Built for edge installs: rack, tower and wall mount formats for non standard technical rooms.

EDGE quote →

🏢

Liebert ITA2

5 to 20 kVA: compact double conversion

Dense double conversion for tight rooms that need more power without moving to three phase.

ITA2 quote →

🧩

Three phase and modular

APM, Trinergy: data centres

For data centres and industrial loads, Vertiv offers large modular three phase systems. See our modular UPS page.

Modular UPS →

🔧

Maintenance and batteries

Existing fleet: Vertiv and Liebert

Preventive maintenance, battery replacement and out of warranty repairs on your in service equipment.

Service and maintenance →

Which line for your load?

VERTIV AND LIEBERT SINGLE PHASE LINESEDGE0.5 to 3 kVAPSI50.75 to 3 kVAGXT50.5 to 20 kVAITA25 to 20 kVA0.51351020Capacity (kVA)

Quick rule: line interactive (PSI5, EDGE) for network gear, double conversion (GXT5, ITA2) for servers and sensitive loads. Beyond 20 kVA, move to three phase systems.

New units and warranty: on larger new units, startup and commissioning is performed by Vertiv to preserve the factory warranty. GDF Technologies handles the rest: load analysis, model selection, quoting, ordering and delivery coordination.

Frequent questions

GXT5 or PSI5: which one?+
The PSI5 (line interactive) suits switches, routers and small servers. For servers, storage and any sensitive load, the GXT5 online double conversion design removes transfer time entirely and fully isolates the load from raw utility power.
Who commissions new units?+
On larger new units, startup and commissioning is performed by Vertiv to preserve the factory warranty. GDF Technologies handles load analysis, quoting, ordering and delivery coordination.
Do you replace GXT and PSI batteries?+
Yes. Our team replaces batteries on the GXT and PSI lines, in shop or on site, and provides preventive maintenance and out of warranty repairs on Vertiv and Liebert equipment.
Do you deliver across Canada?+
Yes. We deliver and support Vertiv and Liebert UPS systems across Canada, with 24/7 emergency phone support at 514 252-8324.

Tell us about your Vertiv project

Describe your need: load to protect, runtime target, space constraints. We come back with a recommended model and a price.