Complete Battery Lifecycle Management

From initial inspection to final recycling, GDF handles every step.

🔍

Testing & Diagnostics

Voltage, impedance and temperature measurements. Infrared thermography, real-load capacity testing and full condition report.

✅

Certified Replacement

VRLA/AGM and Lithium-Ion. Hot-swap where supported. OEM batteries or GDF-certified equivalents, manufacturer warranty maintained.

🔧

ASC-UPS Calibration

Critical post-replacement step: recalibrating the UPS microprocessor for accurate runtime estimates and to prevent premature low-battery alarms.

📋

Preventive Maintenance

Integrated into scheduled visits: semi-annual VRLA checks, annual Li-ion inspections, condition reports and replacement planning.

♻️

Compliant Recycling

Collection, transport and processing through certified channels. Proof of treatment provided. Full provincial regulatory compliance.

🚨

24/7 Emergency Response

Battery failure in the middle of the night? Our technicians respond rapidly across Quebec and all of Canada.

Technologies

VRLA vs Lithium-Ion: Which Technology Is Right for You?

Each technology has its advantages. We guide you to the optimal solution for your site and budget.

🔋

VRLA / AGM

Proven technology, lower initial cost. Typical service life 3 to 5 years depending on temperature and cycling. Semi-annual maintenance recommended. Compatible with virtually all UPS systems in the field.

⚡

Lithium-Ion (Li-Ion)

8 to 10 year lifespan, reduced weight, fast recharging, superior cycle tolerance. Higher initial cost but lower TCO over time. Ideal for new deployments or modernization projects.

🔥

Flame-Retardant (UL94-V0)

Mandatory in medical, mining and government environments under CSA and NFPA codes. Reduced gas emissions, UL94-V0 certified enclosures. GDF supplies and installs across Canada.

⚠️

Risks of Non-Certified Batteries

Reduced runtime, overheating risk, voided manufacturer warranty and loss of UL safety certifications. GDF supplies only OEM or certified-equivalent batteries.

Battery End-of-Life
or Active Alarm?

Share your UPS model, province and urgency level. We plan the intervention quickly.

📧 Contact GDF TechnologiesContact Form

Response guaranteed within 1 business day

UPS Battery Replacement in Canada

GDF Technologies performs certified UPS battery replacement (VRLA/AGM and Lithium-Ion) across Canada. Our technicians service APC, Eaton, Vertiv Liebert, Tripp Lite, XPC, Delta, Toshiba and Mitsubishi systems. Every intervention includes capacity testing, ASC-UPS post-replacement calibration and a condition report.

Post-Replacement Calibration

UPS microprocessor calibration after replacement is a critical step often overlooked. Without recalibration, the UPS cannot accurately estimate available runtime with new batteries. GDF performs this calibration systematically on every battery replacement.

Flame-Retardant Batteries

Flame-retardant batteries (UL94-V0) are mandatory in many regulated environments: hospitals, mines and government buildings. GDF Technologies supplies and installs these batteries, compliant with CSA and NFPA codes, across Canada.