Single-Phase UPS
Canada
Sales, installation, certified commissioning, and 24/7 maintenance for single-phase UPS systems from 300 VA to 20 kVA. APC, Eaton, Vertiv, XPC, Delta, Toshiba, Mitsubishi, anywhere in Canada.
A single-phase UPS (uninterruptible power supply) protects critical equipment from 300 VA to 20 kVA, servers, networks, medical equipment, and telecom systems. Unlike three-phase UPS systems designed for high-power installations, single-phase UPS connects directly to a 120V or 208V circuit. GDF Technologies sells, installs, and maintains all major single-phase UPS models across Canada with certified commissioning to activate manufacturer warranties.
Line Interactive or Online Double Conversion?
The right choice depends on the criticality of your equipment, power grid quality, and your tolerance for interruption.
Line Interactive
Automatic voltage regulation (AVR), effective protection, minimal transfer time (2 to 6 ms). Ideal for workstations, networks, and non-critical peripherals. Models: APC SMT, Eaton 5P.
Online Double Conversion
Zero transfer time, full electrical isolation, pure sine wave output. Essential for critical servers, labs, edge IT, and sensitive equipment. Models: APC SRT, Eaton 9PX, Vertiv GXT5, XPC T91/P91.
Runtime & Batteries
Additional battery modules (EBM/EBP), graceful shutdown via PowerChute/IPP, compliant VRLA and Lithium recycling. Runtime sizing available on request based on load and target autonomy.
Single-Phase UPS Product Lines We Service
Smart-UPS SMT, Line Interactive
The Smart-UPS SMT is the most widely deployed single-phase UPS in Canadian server rooms and network closets. Thousands of units protect servers, switches, and telecom equipment across Canadian businesses, government agencies, and healthcare facilities. VRLA batteries last 3 to 5 years and should be replaced in complete sets.
- RBC battery replacement (complete sets, matched age/brand)
- Capacitor, fan, and internal component inspection
- Firmware updates and SmartConnect/NMC3 configuration
- Load testing and certified maintenance report
Smart-UPS SMC, Compact Rack
Compact version of the Smart-UPS optimized for network cabinets where space is limited. Very popular in retail environments (POS), small server rooms, and building telecom installations.
- Battery replacement with post-replacement calibration
- Load verification and actual runtime testing
- SNMP/SmartConnect configuration
Smart-UPS SRT, Online Double Conversion
The Smart-UPS SRT is the standard for protecting critical servers, medical equipment, and telecom systems with online double conversion. Zero transfer time, full electrical isolation, and external battery packs (EBP) for extended runtime. Deployed in data centres, hospitals, and government facilities across Canada.
- Battery and external EBP module replacement
- Inverter, bypass, and capacitor diagnostics
- Certified commissioning (manufacturer warranty activation)
- Load bank testing and SAT report
Smart-UPS Ultra (SMUS), Lithium-Ion
The newest Smart-UPS line with lithium-ion batteries. Battery life 2 to 3x longer than VRLA, ultra-compact form factor, reduced weight, and wider temperature tolerance. Ideal for edge computing deployments, micro data centres, and remote sites.
- Certified commissioning and warranty activation
- Firmware management and communication modules
- Lithium battery health monitoring and diagnostics
Back-UPS Pro (BR/BX), Line Interactive
The Back-UPS Pro is the cost-effective choice for protecting workstations, POS systems, lab equipment, and small networks. Bulk battery replacement service available for businesses with multiple deployed units.
- RBC battery replacement (individual or bulk service)
- Overload diagnostics and fault assessment
- Fleet service for multi-unit deployments
Easy UPS (SRV / SRVL / BVS / BVX / 3S), Versatile
The Easy UPS range is Schneider Electric’s cost-effective solution for commercial environments, point-of-sale, small servers, and offices. The SRV/SRVL series delivers online double conversion up to 10 kVA single-phase, while the BVS/BVX provides compact line interactive protection. The Easy UPS 3S covers three-phase needs up to 60 kVA for SMBs. Deployed in retail stores, hotels, clinics, and branch offices across Canada.
- Internal battery and external EBP module replacement
- Certified commissioning and warranty activation
- Fleet service for multi-site deployments (retail, branches)
- Load testing and overload diagnostics
Symmetra LX, Modular
The Symmetra LX was the enterprise standard for Canadian server rooms from 2003 to 2024. Modular architecture with hot-swappable battery and power modules. Thousands of units remain in active service across Canadian government, healthcare, and financial institutions. The NMC2 reached end of life in October 2023, upgrade to NMC3 is required for continued network monitoring.
- SYBT5 battery module replacement (hot-swap, zero downtime)
- Intelligence module (IM) diagnostics and replacement
- NMC2 to NMC3 upgrade for continued network monitoring
- Migration analysis: Symmetra LX to Smart-UPS SRT or Galaxy VS
Eaton 9PX / 9PX G2, Online Double Conversion
The 9PX is Eaton’s flagship single-phase UPS for protecting critical servers and network equipment. Massively deployed in government server rooms, hospitals, and financial institutions across Canada. The G2 offers improved efficiency and the Li-ion version (9PX G2-L) extends battery life to 8 to 10 years.
- Internal battery and external EBM module replacement
- Firmware updates and Gigabit network card configuration
- Certified commissioning (manufacturer warranty activation)
- Load testing and capacitor inspection
Eaton 9SX, Compact Double Conversion
Cost-effective alternative to the 9PX for standard IT deployments. Same online double conversion topology in a slightly different form factor. Common in SMBs, educational institutions, and regional government sites across Canada.
- Battery and EBM module replacement
- Fault diagnostics and repair
- Firmware updates
Eaton 5P / 5PX G2, Line Interactive
The 5P/5PX range covers IT and light industrial needs. Reliable protection for network switches, routers, workstations, and small servers. Popular in multi-site deployments (retail, hospitality, education).
- Battery replacement with calibration
- Overload and fault diagnostics
- Fleet service for multi-unit deployments
Eaton 5E / 5SC, Entry Level
Basic protection for workstations, POS terminals, and small equipment. Battery replacement particularly valuable for businesses with multi-unit fleets (retail stores, branches).
- Bulk battery replacement
- Upgrade assessment to 5P/9PX if loads increase
Eaton 9155 / FERRUPS, Installed Fleets
The 9155 and FERRUPS remain in service across many Canadian government and industrial installations. Eaton retires the FERRUPS FE in 2027, ending contract coverage. GDF Technologies provides batteries, parts, and service for these legacy systems plus migration analysis to current-generation 9PX G2 or 93PR.
- Battery and capacitor replacement
- Legacy system fault diagnostics
- Migration analysis: 9155/FERRUPS to 9PX G2 or 93PR
Vertiv GXT5, Online Double Conversion
The GXT5 is Vertiv’s flagship single-phase UPS for data centres, telecom, and critical facilities. ECO mode for improved energy efficiency. Massively deployed in Bell and Telus central offices, hospitals, and government sites across Canada.
- Internal battery and external EBC module replacement
- Inverter diagnostics and firmware updates
- SNMP/Modbus configuration and BMS integration
- Load testing and maintenance report
Liebert PSI5, Line Interactive
The PSI5 replaces the popular PSI and offers cost-effective protection for light servers, networking, and telecom equipment. Popular in remote site deployments and branch offices.
- Battery replacement with calibration
- Runtime testing and fault diagnostics
- Fleet service for multi-unit deployments
Liebert ITA2, High Performance Double Conversion
The ITA2 bridges the gap between single-phase and small three-phase. Ideal for mid-size server rooms, laboratories, and telecom installations requiring online double conversion above 5 kVA.
- Battery replacement and preventive maintenance
- Fault diagnostics and repair
- Certified commissioning and SAT report
Liebert GXT4 / GXT3, Legacy
The GXT4 and GXT3 remain massively deployed in Canadian data centres, telecom facilities, and government installations. Batteries and parts still available. GDF Technologies provides ongoing service and migration planning to the GXT5.
- Battery and EBC module replacement
- Discontinued system fault diagnostics
- Migration analysis: GXT4/GXT3 to GXT5
XPC T91 / P91, Online Double Conversion
GDF Technologies is a certified XPC partner in Canada. The T91 (tower) and P91 (rack) lines deliver high-density online double conversion ideal for servers, POS, digital signage, and edge computing. On-site commissioning and warranty activation by GDF.
- Certified commissioning and XPC warranty activation
- Battery and EBM module replacement
- Direct manufacturer technical support via GDF
- SNMP configuration and network integration
XPC J60 / P91Li, Lithium
XPC lithium solutions deliver 10+ year battery life in an ultra-compact form factor. Ideal for network cabinets, POS terminals, and edge deployments where space and longevity are priorities.
- Commissioning and XPC warranty activation
- Lithium battery health monitoring
- Manufacturer technical support via GDF
Delta Amplon RT / RT Pro, Online Double Conversion
Delta’s Amplon RT line delivers high-efficiency online double conversion for SMBs, network cabinets, and edge IT deployments. Popular for its reliability and value in multi-site Canadian deployments.
- Battery and EBM module replacement
- Commissioning and SNMP configuration
- Preventive maintenance and load testing
Delta Agilon VX, Entry Level
Cost-effective solution for workstation and small equipment protection. Bulk battery replacement for multi-unit deployments.
- Bulk battery replacement
- Upgrade assessment
Toshiba 1600XP / 1600XPi, Online Double Conversion
Toshiba’s 1600XP line delivers isolated online double conversion for medical, industrial, and laboratory applications. Known for generator compatibility and low input harmonics. Industry-leading 3-year on-site warranty from the manufacturer.
- Battery and external cabinet replacement
- Certified commissioning and load testing
- Fault diagnostics and repair
- RemotEye configuration and remote monitoring setup
Toshiba T1000, Compact
Compact online double conversion from Toshiba for office and small server room applications. Industrial reliability in a reduced form factor.
- Battery replacement with report
- Diagnostics and preventive maintenance
Mitsubishi 7011B, Online Double Conversion
The Mitsubishi 7011B series is known for exceptional industrial reliability and longevity. Deployed in financial, medical, and government installations across Canada where power quality is non-negotiable. Manufactured in the USA by MEPPI.
- Battery replacement and preventive maintenance
- Specialized Mitsubishi diagnostics and repair
- Load testing and certified report
- Escalated technical support via MEPPI when needed
Single-phase UPS service, batteries, or replacement planning
Tell us your UPS model and what you need. Quote returned within one business day.
Our technicians service all single-phase UPS brands, APC, Eaton, Vertiv, XPC, Delta, Toshiba, Mitsubishi, anywhere in Canada. Whether you need a battery replacement, certified commissioning, or a migration assessment, one form is all it takes.
Single-Phase UPS Quote Request
Batteries, parts, preventive maintenance, commissioning, or migration planning.
Or email support@gdftech.com · Call (514) 252-8324
Single-Phase UPS Services Canada
From selection to end of life, one partner for your entire single-phase UPS fleet.
Assessment & Selection
Load/runtime analysis, topology selection (line interactive vs online), tower or rack format, local distribution.
Commissioning & Warranty
Certified manufacturer startup to activate warranty. SNMP/Modbus configuration, functional testing, and commissioning report.
Preventive Maintenance
Scheduled visits, battery testing, thermography, environmental checks, and firmware updates.
Batteries & Recycling
Certified VRLA and Lithium replacement, post-replacement calibration, compliant disposal with recycling proof.
24/7 Emergency
Rapid response across Quebec and Canada-wide. Remote triage, temporary solutions, critical parts plan available.
Replacement & Migration
End-of-life equipment swap, lithium migration, load testing, and secure decommissioning.
Frequently Asked Questions, Single-Phase UPS
What is the difference between line interactive and online double conversion UPS?
Why is certified commissioning necessary?
How long do single-phase UPS batteries last?
Can GDF Technologies install a rack-mount single-phase UPS?
Which single-phase UPS brands does GDF support?
How do I choose the right capacity for a single-phase UPS?
Single-Phase UPS in Canada
GDF Technologies distributes, installs, and maintains single-phase UPS systems from 300 VA to 20 kVA across Canada since 2012. Our certified technicians service APC Smart-UPS, Eaton 5P/9PX, Vertiv Liebert, XPC, Delta, Toshiba, and Mitsubishi for commissioning, preventive maintenance, UPS battery replacement, and 24/7 emergencies.
Line Interactive vs Online Double Conversion
Line interactive (APC SMT, Eaton 5P) offers effective and economical protection for non-critical loads. Online double conversion (APC SRT, Eaton 9PX, Vertiv GXT5, XPC T91/P91) guarantees zero transfer time and full electrical isolation for servers, labs, and sensitive equipment.
UPS Commissioning & Warranty
Certified commissioning by a qualified technician is required to activate manufacturer warranty on most professional UPS (APC Smart-UPS, Eaton 9PX, Vertiv GXT5, XPC). GDF Technologies performs validated startups in Quebec, Ontario, British Columbia, Alberta, and all provinces. Preventive maintenance and consultation services available.
Contact GDF Technologies