A central emergency-lighting inverter must be selected from the connected lighting duty, autonomy, voltage, transfer, monitoring, listing and authority requirements. [1] [2] [3] [4]
Operating decision
The decision begins with the function to preserve, support time, source states, consequence of interruption and accepted exposure during maintenance. A technology name or nominal rating does not replace those inputs. Selection remains conditional while load, voltage, environment, bypass or operating authority is unknown.
A Canadian manufacturer describes its Borealis emergency-lighting inverter as a double-conversion platform with battery runtime, isolation and maintenance-bypass considerations. [2]

Figure 1: Engineering decisions.
Evidence basis
A separate paper from the same Canadian manufacturer describes three-phase monitoring, phase-loss detection, event logging and building-automation interfaces. [3]
The applicable code edition, product certification and authority acceptance remain project-specific and must be documented before a compliance claim. [4]
Manufacturer sources define published capabilities for specific families and configurations. They are used for their own facts, not as generic values. The internal reference connects those facts to site measurement, safety, maintainability and acceptance testing. Any claim that depends on model, code or region is rechecked at project time.

Figure 2: Evidence roles.
Design inputs
The survey records average and peak load, watts and VA, inrush, voltage, phases, conductors, grounding, runtime, generator, bypass, protection, temperature, ventilation, delivery route, communications and work window. Each value receives a status: observed, measured, documented, stated, calculated or unresolved.
An unresolved value is not automatically converted into conservative margin. Some unknowns can be carried as assumptions with an owner and expiry. Others block the project because they determine safety, capacity, source compatibility, storage, certification or maintainability.

Figure 3: Subject-specific decision matrix.
Option comparison
| Option | Benefit to verify | Main exposure | Required evidence |
|---|---|---|---|
| Baseline configuration | Familiar process | Inherited assumptions | Current site and OEM evidence |
| Targeted change | Addresses one constraint | New service boundary | Test of the affected state |
| Coordinated replacement | Standardizes assets | Larger cutover scope | Complete register and rollback plan |
The comparison uses one horizon for purchase, installation, bypass, cooling, startup, maintenance, consumables, spares, support and retirement. A saving is published only when tariff, load profile, cycling, replacements and uncertainty are stated.

Figure 4: Operating states.
Operating and maintenance states
The state register covers normal operation, source loss, stored-energy support, alternate source, static bypass, maintenance bypass, isolation and return. It records load path, power quality, reserve, energized sources, permitted duration, alarms, stop conditions and rollback.
No live-work sequence is published. Switching and isolation belong in a site-specific method performed by qualified personnel using the exact manual, safety program, instruments, communications, hold points and approved rollback.

Figure 5: Acceptance record.
Procurement and commissioning
The purchase record binds model, voltage, rating, storage, bypass, accessories, network interface, certification, warranty and startup. A substitute is checked with its own source. Commissioning measures values, alarms, transitions and final state against criteria established before the test.
The UPS consultation and installation services can be used to define the survey, commissioning or maintenance scope that must produce this site evidence.
Measurement limits
A technical sheet, case study and self-test answer different questions. The sheet states a published capability. The case reports an attributed result. The self-test confirms a limited internal function. None replaces a measured runtime test, witnessed transfer or analysis of untested states.
Approval record
Approval retains the design basis, sources, calculations, assumptions, as-built drawings, settings, tests, deficiencies, corrections, owners and next review date. The project is reopened after load growth or a change in source, room, firmware, battery, support or operating objective.
Subject-specific decision register
Four decisions govern this publication: connected emergency-lighting load, autonomy required by the governing design, listing and authority acceptance and transfer, phase monitoring and bypass. They form a reviewable register instead of a generic checklist. Each row has an input, source, owner, acceptance condition and consequence when evidence is missing.
| Decision | Required evidence | Stop condition |
|---|---|---|
| Connected emergency-lighting load | The connected emergency-lighting load in watts and VA, by circuit, from the lighting design and panel schedule | Hold sizing until the connected emergency load is taken from the lighting design, not estimated |
| Autonomy required by the governing design | The required autonomy in minutes from the governing building and fire code and the design basis (for example 30 or 90 minutes) | Hold if the required minutes are not cited from the governing code and design |
| Listing and authority acceptance | The inverter listing and any certification the authority having jurisdiction requires, and the authority acceptance for emergency use | Do not proceed without the required listing and the authority acceptance on record |
| Transfer, phase monitoring and bypass | The transfer time to emergency, the phase-monitoring scheme, and the maintenance-bypass provision, against the code transfer requirement | Hold if transfer time or phase monitoring does not meet the code, or no maintenance bypass exists |
The site survey records load, source, room, environment, bypass, delivery route and operating constraints [5]. Calculations and assumptions retain units, load state and source [6]. This connection prevents a catalogue value or a case outcome from becoming the default value for a new installation.
The state register separates normal operation, source loss, stored-energy support, static bypass, maintenance bypass, isolation and return [7]. It states what supplies the load, remaining protection, energized sources, permitted duration, alarms and the point where work must stop.
Monitoring identifies card, firmware, protocols, network segment, accounts, logs and alarm owner [8]. Read-only remains the starting point. A remote command or automated shutdown requires an approved need, dependency map and tested rollback.
Commissioning establishes criteria before testing and retains measurements, events, deficiencies, corrections and final state [9]. The service agreement states response, exclusions, spares, maintenance window, report and next lifecycle decision [10].
Sources
- GDF Technologies internal knowledge library, Emergency Lighting Inverters for Canadian Facilities. Local library: Standards, Safety & Compliance/Emergency Lighting Inverters for Canadian Facilities.md
- Canadian OEM, Borealis Emergency Lighting Inverter White Paper. https://www.alwayson.com/wp-content/uploads/Borealis-White-Paper_Always-On-UPS-Systems-Rev-2020-05-27.pdf
- Canadian OEM, Borealis Series with Three-Phase Monitoring. https://www.alwayson.com/wp-content/uploads/Borealis-Series-Three-Phase-Monitoring.pdf
- GDF Technologies internal knowledge library, Canadian and US UPS Installation Compliance Field Guide. Local library: Standards, Safety & Compliance/Canadian and US UPS Installation Compliance Field Guide.md
- GDF Technologies internal knowledge library, UPS Site Survey and Requirements Capture. Local library: UPS Solutions & Quotes/UPS Site Survey and Requirements Capture.md
- GDF Technologies internal knowledge library, UPS Engineering Calculations and Independent Design Verification. Local library: UPS Solutions & Quotes/UPS Engineering Calculations and Independent Design Verification.md
- GDF Technologies internal knowledge library, UPS Maintenance MOP Safety Boundaries and Go-No-Go Criteria. Local library: UPS Maintenance/UPS Maintenance MOP Safety Boundaries and Go-No-Go Criteria.md
- GDF Technologies internal knowledge library, UPS Monitoring Cybersecurity and Network Integration. Local library: Monitoring, SNMP & Shutdown/UPS Monitoring Cybersecurity and Network Integration.md
- GDF Technologies internal knowledge library, UPS Commissioning and Acceptance Testing. Local library: Installation & Commissioning/UPS Commissioning and Acceptance Testing.md
- GDF Technologies internal knowledge library, UPS Service SLA Design and Coverage Scoping. Local library: Service Contracts & PM Agreements/UPS Service SLA Design and Coverage Scoping.md
GDF Technologies services every UPS brand covered here, across Canada. See our preventive UPS maintenance plans or call (514) 252-8324 for on site support.
